OL2R
Does any of your critical machines experience continuous high levels of vibrations?
Need to do something about it?
Measurements of dynamic movements are used for critical machines within industries, where large temperature differences or other disturbing factors exist. The need for dynamic measurements is indicated by a high level of vibrations. These high levels can remain even after having performed shaft alignment in cold condition.
There can be a situation where two identical machines behave differently, even though OEM recommendations have been taken into consideration, during the alignment. In order to obtain unique and exact target values, measurements in both hot and cold conditions have to be performed. Thereafter, the difference is used as machine unique target values for precision shaft alignment.
The NXA with the OL2R expansion kit helps you overcome this costly and time-consuming problem.
The OL2R fixtures, combined with the NXA system, will provide you with:
An express set up without using the display unit
A function for continuing the measurement or to save for the future
An express result – the machine’s individual target values
What’s in the case?
The OL2R Fixtures with case
2 pcs of OL2R fixtures, available in mm or in inch
Allen key 5 mm or 3/16 inch
2 pcs of socket cap screws M6 x 650 or UNC 1/4 x 2 inch
Thread tap M6 or 1/4 inch
Allen key 2 mm
Drill 5 mm
4 pcs of batteries, SR44 1,5 v