Fluke Networks LinkIQ Cable + Network Tester

Fluke Networks LinkIQ Cable + Network Tester

  • Validate Cable Performance up to 10GBASE-T via frequency-based measurements
  • Get connected switch data rate, switch name, IP address, port number, and VLAN
  • Detect the PoE class (1-8) and power, and perform a load test
  • Test connectivity to TCP/IP network through IP configuration and ping

Fluke Networks LinkIQ Cable + Network Tester

Product overview: Fluke Networks LinkIQ Cable + Network Tester

  The LinkIQ™ Network+Cable Tester is the trusted cable and network testing solution for validating and troubleshooting cable performance from 10BASE-T to 10GBASE-T (10 Mb/s up to 10Gb/s).

  LinkIQ supports Industrial Ethernet (EtherNet/IP, PROFINET, EtherCAT, and others) and is certified by the Ethernet Alliance to IEEE-802.3™ PoE standards. Additional convenient features include Analog and Digital Toning, Port Blink, Remote Office Locators, and integration with LinkWare™ PC software for managing and documenting results.

Validates Cable Performance
  LinkIQ ensures that tested links meet performance requirements. It can measure lengths up to 1,000 feet (305 m) and provide distance to faults such as opens, shorts, and unterminated cable. The included remote ID provides a complete wire map of the cable pairs to identify miswired and split pairs.

Detailed Ping Tests Speed Troubleshooting
  LinkIQ performs IP ping tests that verify connectivity and provides nearest switch diagnostics, including advertised data rate (up to 10GBASE-T), half/full duplex identification, switch name and IP address, port number, VLAN information, and load test up to Class 8 (90 W). With LinkIQ, you can quickly identify key network issues and validate switch configuration without having to use another device.

In-Depth Testing for PoE
  To simplify PoE installation and troubleshooting, LinkIQ displays the pairs where power is provided, showing the different power levels and pairs for dual-signature implementations. LinkIQ performs load testing up to Class 8 (90 W) by placing a load on the connection to ensure that the advertised power is actually being delivered across the cabling infrastructure.

Color Touchscreen
  LinkIQ has a large, gesture-based touchscreen that displays a great deal of information and provides clear, easy-to-use controls such as sliders and a full keyboard. Its simplified TEST function displays results according to what’s plugged into the unit’s single RJ-45 connector. A single USB-C port provides connectivity to your PC for software updates, reporting, and charging.

Integrated with LinkWare PC
 LinkIQ provides complete documentation via LinkWare PC. Up to 1,000 results with descriptive names can be stored in the tester and recalled. Test names and numbers automatically increment when saved (“Annex B-1,” “Annex B-2,” “Annex B-3,” etc.), saving valuable time when you test cables in sequence.

Additional Features

      • Multiple-language interface support: English, German, French, Japanese, Thai, Spanish, Traditional Chinese, Simplified Chinese, Korean, Russian, Italian, Portuguese
      • Cable Toning (compatible with the Fluke Networks IntelliTone™ Probe or Pro3000™) 
      • Blink Port light on switch
      • Compatible with MicroScanner™ PoE Remote Identifiers
      • Color touchscreen
      • Rechargeable Li-Ion battery via standard USB-C port
      • Easy upgrades through USB-C or LinkWare PC
Specifications: Fluke Networks LinkIQ Cable + Network Tester
FeatureDescription
Languages supported in UIEnglish, German, French, Japanese, Spanish, Thai, Traditional Chinese, Simplified Chinese, Korean, Russian, Italian, Portuguese
Weight1 lbs 6 oz (624g)
BatteryType: Lithium-ion, 3.6 V, 6400 mAh
Life: 8 hours typical
Charge time: 4.5 hours
Charging temperature range: 0 °C to +40 °C
Power AdapterInput: 100 to 240 VAC ±10%, 50/60Hz
Output: 15 VDC, 2 A maximum
Class II
Host InterfaceUSB type C
Display800 x 480 color capacitive multi-touch
Dimensions8.5 in x 4.5 in
Operating Temperature0°C to 45°C
Storage Temperature-10°C to +60°C
Operating Relative Humidity0 % to 90 %, 0°C to 35°C
0 % to 70 %, 35°C to 45°C
Operating Altitude4,000 m
3,200 m with ac adapter
VibrationRandom, 2 g, 5 Hz-500 Hz
Drop1 m drop, 6 sides

Active Network Diagnostics

FeatureDescription
Diagnostic ProtocolsLink Layer Discovery Protocol (LLDP)
Cisco Discovery Protocol (CDP)
Fast Link Pulses (FLP)
Internet Control Messaging Protocol (ICMP),
Dynamic Host Configuration Protocol (DHCP)
IP Address SetupLinkIQ address, DNS Server, Gateway for IPv4 or v6 either manually or via DHCP
IP Ping Test ResultsFour response time results for target, DNS Server(s), Gateway, plus average and number lost.
Power Over Ethernet CompatibilityEthernet Alliance Certified to IEEE 802.3af/at/bt,
Hardware negotiation with signature resistance,
Software negotiation with LLDP/CDP
Power Over Ethernet MeasurementsLoaded Voltage (V)
Loaded Power (W)
Port BlinkBlink the light of the connected port

Cable Test Specifications

FeatureDescription
Test PortShielded 8-pin modular jack accepts 8-pin modular (RJ45) plugs.
Commissioning Autotests10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, Wire map Only.
Test Speed: 6 seconds for lengths < 70 m
Cable TypesBalanced twisted-pair cabling
Unshielded twisted-pair
Screened twisted-pair
2-pair and/or 4-pair
Wire Map-Only TestsDocument wire map
Length of each pair
Diagnose split pairs
User selectable T568A or T568B
User selectable crossover settings (Straight through, Half-crossover, Full-crossover)
Test speed: 1 second for lengths < 120 m
Length (Maximum)305 m (1000 ft)
Nominal Velocity of Propagation (NVP)User settable
Tone GeneratorGenerates digital tones compatible with Fluke Networks IntelliTone probe.
Generates analogy tones compatible with general analog probes.
Remote ID LocatorsUse remote ID terminations to identify up to 7 unique ports or office outlets

Fluke Networks LinkIQ Cable + Network Tester

      • Validate Cable Performance up to 10GBASE-T via frequency-based measurements
      • Get connected switch data rate, switch name, IP address, port number, and VLAN
      • Detect the PoE class (1-8) and power, and perform a load test
      • Test connectivity to TCP/IP network through IP configuration and ping
Read Our Latest News

News & Articles

Vibration Camera IRIS MX high-speed 1400 FPS in HD  visualizing the motion of the entire machine, its structure and base, and the surrounding environment to determine the root cause.